Rockwell Automation 9329 Drive Application Software Tension Control Gen. Units User Manual
Page 48

FM – Tension Control
Drive Application Software – page 48 of 52
The following table is a functional list of the Process Line status word
[DLx_DrvStatProcLn]
Bit
Output Signal
Description
00
Fault
Drive Fault or a System Fault
01
Running
Drive is Running / not stopping
02
Reserved
03
Motor Ctrl On
Motor is being control (Motor POWER)
04
Reserved
05
Jogging
section Jogging
06
Rotational Reverse
Under Wind
07
Tension Control On
Selected mode of Tension control is enabled
08
Zero Speed
Below Zero Line speed set point
09
Diameter Calculation Active
Future
10
Reserved
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
16
Enable Loss Fault
Drive Enable lost
17
Fail to Run fault
Drive failed to start
18
Communication fault
NA – not support
19
Message fault
NA – not support
20
Motor Overload Fault
Overload alarm from drive
21
Motor Overtemperature Flt
Over temperature alarm from drive
22
Motor Blower Loss Fault
Motor blower has stopped or tripped off
23
Reserved
24
Reserved
25
Reserved
26
Reserved
27
Reserved
28
Reserved
29
Reserved
30
Operate Permissive
Use in line control logic to command a
coordinated line ramp stop.
31
On Permissive
Loss of permissive resets start command.
The drive will coast stop or ramp stop
depending on configuration