Mounting cutouts panel mounting – Rockwell Automation 6182 Industrial Computer for the Windows CE Operating System User Manual
Page 25
Installation
2–5
Publication 6182-UM001D-EN-P
The following figure provides the dimensions for making the panel or
enclosure cutout for the RAC6182 Industrial Computer.
Table C
Mounting Cutout Sizes
Display Size
Height
Width
7.7 in. version with keypad
197.8 [7.79]
295.8 [11.65]
12.1 in. version with touchscreen
256.8 [10.11]
337.6 [13.29]
12.1 in. version with keypad
256.8 [10.11]
389.9 [15.35]
To install the RAC6182 Industrial Computer in a panel:
ATTENTION: Disconnect all electrical power from the
panel before making cutout.
Make sure the area around the panel cutout is clear.
Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.
Failure to follow these warnings may result in personal
injury or damage to the panel components.
To install the RAC6182 Industrial Computer in a panel:
1. Cut an opening in the panel using the panel cutout dimensions
provided on Page 2-5.
2. Make sure the RAC6182 Industrial Computer sealing gasket is
properly positioned on the terminal. This gasket forms a
compression type seal. Do not use sealing compounds.
3. Place the RAC6182 Industrial Computer in the panel cutout.
Mounting Cutouts
Panel Mounting