15–4 System

Troubleshooting

Publication 6182-UM001D-EN-P

Is the video driver properly installed?

Reboot the RAC6182 Industrial Computer with the external monitor

connected and powered up.

If the Power On LED indicator does not come on:

Check the power supply connections and front bezel cable

connections on the processor board.

Check the power connections.

The RAC6182 is capable of resetting the Windows CE registry to the
factory default. This may be required if an application damages the
registry information and the RAC6182 will no longer boot.

Jumper J2 on the RAC6182 CPU board is used to boot the RAC6182
Industrial Computer into debug mode, which will load the factory-
default Windows CE registry.

To change the J2 jumper:

1. Disconnect power from the RAC6182 Computer.

2. Disconnect any device connected to COM2 port.

3. Follow the procedures on Page 4-2 to open the computer chassis.

Resetting the Windows

CE Registry