beautypg.com

Rockwell Automation 1770-M12 Mass Storage Systems User Manual

Page 24

background image

Installing Your Mass Storage System

Chapter 3

3Ć9

Figure 1.10

How to Connect the Twinaxial Cable to the 1770ĆM11 System

SERIAL CHANNEL J22

1

SH

2

IN

1

SH

2

OUT

11966

e. loosen three consecutive screws to one channel (either the IN or

OUT channel) of the 1770-M11 system

f. wrap the blue wire around the screw, labeled: 1; secure the screw

g. wrap the shield drain wire around the screw, labeled: SHIELD;

secure the screw

h. wrap the clear wire around the screw, labeled: 2; secure the screw

4. Select the communication rate by sliding the BAUD RATE switch to the

correct selection. (Refer to chapter 4 page 4-5.)

5. Plug the power cable into the power outlet.

If you need additional storage, you can connect up to three 1770-M10 systems
by performing these steps (Figure 1.11):

This manual is related to the following products: