beautypg.com

24v dc connection, Digtial reference input, Encoder connection – Rockwell Automation 1395 Digital Reference Adapter Board User Manual

Page 21

background image

Chapter 4

Installation

4-7

24V DC Connection

A properly sized 24V DC power supply is required to power the 24 volt
inputs. Refer to

Figure 4.4

.

Digtial Reference Input

The Digital Reference Adapter Board contains one digital reference
command for the drive. The board is set up by default for the encoder input
signal to be single channel, dual edge (i.e. both the rising and falling edges
are used by the counting logic.). The hardware is configured for +5VDC
signal inputs with jumpers J6 and J7 in the 1-2 position. For a +12V DC
signal the jumpers must be placed in the 2-3 position.

Encoder Connection

Figure 4.6 shows the typical encoder connection used as a signal for the
digital reference input. This encoder can be machine mounted or mounted
on the motor of the lead section.

Figure 4.6

Encoder Connections

ENCODER CH B

23

24

25

26

TB3

ENCODER CH A

ENCODER CH A

ENCODER CH B

14

13

CHANNEL B

Encoder

CHANNEL A

CHANNEL A

CHANNEL B

+

C

POWER SUPPLY

COMMON

+12V DC POWER

SUPPLY