beautypg.com

Mounting the switch body, Setting actuator to switch alignment – Rockwell Automation 440G-LZ Guard Locking Switch User Manual User Manual

Page 17

background image

Rockwell Automation Publication 440G-UM001A-EN-P — November 2013

17

Installation and Wiring

Chapter 3

Mounting the Switch Body

Three M5 fasteners (not provided) are required for proper mounting to a
rigid guard door frame.

Setting Actuator to Switch
Alignment

There are three ways to achieve proper alignment.

1. By setting gap “G”
2.5 mm (0.09 in.) [0…5 mm (0…0.19 in.)]

2. By mounting hole alignment ”H”
6.5 mm (0.25 in.) [4…9 mm (0.15…0.35 in.)]

3. Using the alignment guide
provided

3 x M5

G

H