beautypg.com

Mounting the assembled actuator, Removal of the actuator plug – Rockwell Automation 440G-LZ Guard Locking Switch User Manual User Manual

Page 16

background image

16

Rockwell Automation Publication 440G-UM001A-EN-P — November 2013

Chapter 3

Installation and Wiring

Mounting the Assembled
Actuator

Ensure two fasteners are used with at least one fastener fitted close to the
actuator bracket bend.

The following drawings show mounting possibilities when attaching to
extruded aluminum profile and flat surface guard doors.

Removal of the Actuator Plug

This plug may be broken out from the actuator if a through hole is
required to prevent a food trap when mounted on the hazard side of a
guard door.

The plug can be broken out by using a screwdriver and twisting until it
comes apart.