beautypg.com

Chap02_new, Safety concept, Chapter – Rockwell Automation 440G-LZ Guard Locking Switch User Manual User Manual

Page 11: Introduction, Safety certification

background image

Rockwell Automation Publication 440G-UM001A-EN-P — November 2013

11

Chapter

2

Safety Concept

Safety Standards Applied to
the Guardmaster 440G-LZ
Guard Locking Switch

The Guardmaster 440G-LZ satisfies applicable requirements in the
following standards related to functional and machinery assembly:

IEC 60947-5-1: 2003+A1: 2009
IEC 60947-5-3: 1999/A: 2005
IEC 61508:2010 SIL 3
IEC 62061:2005 SIL 3
EN/ISO 13849-1:2008/AC: 2009 Performance Level e (PLe), Category

4

EN/ISO 14119:2013
UL 508 17

th

Edition dated 3/19/2013

Introduction

This section describes the safety performance level concept and explains
how the Guardmaster 440G-LZ meets the requirements for SIL 3, Cat. 4 or
Performance Level “e” (PLe) applications.

Safety Certification

The Guardmaster 440G-LZ is certified for use in safety applications up to
and including SIL 3 according to IEC 61508 and IEC 62061 with a proo

f test

interval of 20 years, Performance Level PLe and Category 4 in compliance
with ISO 13849-1.

Safety requirements are based on the standards applicable at the time of
certification.

The TÜV Rheinland group has approved the Guardmaster 440G-LZ for use
in safety-related applications where Performance Level “e” is required for
the door position and lock monitoring functions.

The 440G-LZ must be installed in accordance with the applicable
regulation and standards.

While the 440G-LZ can be used for SIL 3, PLe and Category 4 applications,
the installer must comply with guard requirements (e.g. EN/ISO13854
and EN/ISO 13857) and in some cases also minimum (safe) distance
requirements (e.g. EN/ISO 13855).