beautypg.com

Configuring the sst-pfb-slc scanner, Configuring the sst-pfb-slc scanner -4 – Rockwell Automation 160PD1 160 Profibus Communication Module User Manual

Page 30

background image

6–4

Using the 160-PD1 on Profibus

Configuring the SST-PFB-SLC
Scanner

The following steps are performed to configure the SST-PFB-SLC
scanner using the SST PROFIBUS configuration software tool.

Click on the (+) sign of the Masters folder in the Library window to
open the SST sub-folder. Available DP masters are displayed in this
sub-folder.

Then, double-click the SST-PFB-SLC MASTER in the Masters
folder in the Library window to add the scanner to the network.
A user-defined Name and Description can be given to the scanner.
In our example the scanner will be Station 0 on the network.

The Parameter tab is not shown here as the default settings are used.

Connection and Baud Rate settings configure how the software tool
will communicate with the CONFIG RS232 port on the scanner.

Click on the COM Port tab.

Accept the settings in our example (COM1 on the PC at 115200 bps
baud rate), as shown below.

When you click OK to accept these settings, the scanner will appear
in the Network window.