Mark 95FT Series

Sanitary "Flow Through" Back Pressure Regulators

Starting with the features and benefits associated with

the superior design of the Mark 95, Steriflow Valve has

added a flow-through option that creates more applica-

tion potential. The MK95FT can eliminate a portion of

the by-pass line components by allowing the back pres-

sure regulating valve to be installed in the primary line

– not in the separated by-pass line.

The Mark 95FT is often found in liquid services such
as WFI loops, CIP lines and filling lines. The valve is
normally closed, allowing flow to pass straight through
to downstream users. When demand downstream is
reduced and pressure builds and reaches the setpoint,
the Mark 95FT will open to relieve and maintain con-
stant pressure. This design allows for elimination of
pipe "T's" and elbows, reduction of weld joints, sim-
plified by-pass piping and easier, quicker installation.
Due to the unobstructed flow path through the valve,
very little to no pressure loss through the valve can
be expected. This is a key reason the MK95FT can be
installed directly into the primary process piping.

Valve

Size

Dimensions (inches)

Weight

Lbs

A

B

C

D

E

3/4" 3.29 8.50 1.50 5.70 6.58

19

1"

4.00 8.50 1.64 5.70 8.00

21

1-1/2" 4.24 10.5 2.53 7.25 8.48

41

2"

5.34 17.5 2.96 9.50 10.7

91

3"

5.34 18.0 3.46 9.50 10.7

99

Valve

Size

Dimensions (mm)

Weight

Kgs

A

B

C

D

E

DN20 84

216

38

145 168

8,6

DN25 102 216

42

145 203

9,5

DN40 108 267

64

184 214

19

DN50 136 445

75

241 271

41

DN80 136 457

88

241 271

45

D

B

C

A

A

E

C

By-pass

Outlet

Inlet

1

4

5

3

2

WFI RESERVOIR

1. MK95 (1 welded clamp

connection on inlet piping)

2. 90° "L" elbow (2 welds)

3. 90° "L" elbow (1-2 welds)

4. 90° "L" elbow (2 welds)

5. 180° "T" connector (3 welds)

1. MK95FT (3 welds for clamp

connection in pipe)

2. 90° "L" elbow (2 welds)

3. 90° "L" elbow (2 welds)

WFI RESERVOIR

2

3

1

MK95FT solution:

A typical MK95 pump by-pass line

looks as follows:

CRN Registration Number Available

Based on US tri-clamp ends. Consult factory for DIN and ISO

tri-clamp end dimensions