beautypg.com

Steriflow JSB Series User Manual

Page 2

background image

-2-

JSB S

erieS

B

io

-P

harma

G

aS

B

ack

P

reSSure

r

eGulatinG

V

alVe

s

peciFications

Sizes:

1/2" (DN15) & 3/4" (DN20)

Ends:

Clamp, Weld-stub or NPT ends

Soft Seat Materials for ANSI Class VI Shut-Off:

• PTFE to +252°F (122°C) continuous or 275°F (135°C)

intermittent [not to exceed 15 min. in a one hour
period]

FDA, USP Class VI

• PEEK to +350°F (176,7°C) FDA, USP Class VI

Body Material:

316L SST

Diaphragm Material:

PTFE-based Jorlon; FDA, USP

Class VI

Maximum Inlet Pressure:

150 psig (10,5 bar)

Spring Ranges:

8–40 psi (0,06–2,8 bar); 35–60 psi

(2,4–4,1 bar); 50–125 psi (3,4–8,6 bar)

Flow Characteristics:

• High Flow: Trim Cv 0.8; Cv for relief valve

sizing is 1.9

• Low Flow: Trim Cv 0.5; Cv for relief valve

sizing is 0.6

Surface Finish:

ASME BPE SF5, 20 Ra μin

(0,5 Ra μm) electropolish as standard.

Options:

• Panel Mounting
• Captured Vent
• Inlet-Outlet Gauge

o

ptions

Panel Mount Option

Captured Vent Option (1/8" NPT)

o

ption

D

eFinition

Captured Vent

The captured vent design is for maximum safety for the user when handling toxic or hazardous media. It
features a 1/8" FNPT port located on the spring housing. The user can easily tube this vent to a safe location.

Panel Mount

The panel mount feature requires a panel cut out of 1-1/2" allowing insertion of the threaded spring hous-
ing, and a panel mount ring to secure the regulator against the panel.