Steriflow JSRLF Series User Manual

Page 2

background image

-2-

JSRLF S

eRieS

L

ow

F

Low

P

ReSSuRe

R

educing

V

aLVe

s

peciFications

Sizes:

1/4" (DN8), 3/8" (DN10), 1/2" (DN15)

End Connections:

Tri-Clamp, Tube Weld End and NPT

Soft Seat Materials for ANSI Class VI Shut-off

• PTFE to +252°F (122°C) continuous or 275°F

(135°C) intermittent [not to exceed 15 min. in a one
hour period]

FDA, USP Class VI

PEEK to +350°F (177°C), FDA & USP Class VI

Body Material

ASTM A479 316L SST

Contact factory for other body/trim/seat materials

Diaphragm Material:

Jorlon, PTFE

TM

, FDA & USP Class VI

Maximum Inlet Pressure:

Tube End & Tri-Clamp: 450 psig (31,0 bar)

NPT: 4000 psig (276 bar)

Pressure at Maximum Temperature:

Tube End and Tri-Clamp: 450 psi @ 350°F (31,0 bar @

177°C) with PEEK seats; 450 psi @ 150°F (30,1 bar @

66°C) with PTFE seats

NPT: 2165 psi @ 350°F (149 bar @ 177°C) with PEEK

seats; 3600 psi @ 150°F (248 bar @ 66°C) with PTFE

seats

Surface Finish:

ASME BPE SF5, 20 Ra, µin (0,5 Ra, µm) electropolish

standard

ASME BPE SF1, 20 Ra, µin, (0,5 Ra µm), non-EP is

optional, as are other finishes

Maximum Pressure Drop:

Tube End and Tri-Clamp: 450 psi (31,0 bar)

NPT: 3000 psi (207 bar)

Spring Ranges

5 – 50 psi (0,3 – 3,4 bar)

25 – 100 psi (1,7 – 6,9 bar)

50 – 150 pis (3,4 – 10,3 bar)

25 – 250 psi (1,7 – 17 bar)

100 – 450 psi (7 – 30 bar)

200 – 750 psi (14 - 52 bar) - NPT only

Flow Capacities:

Cv 0.012, Cv 0.03, Cv 0.08, Cv 0.20

Options

Panel Mounting

Captured Vent

Self Relieving - Available with PTFE seats

o

ptions

Panel Mount Option

Captured Vent Option (1/8" NPT)

o

ption

D

eFinition

Captured Vent

The captured vent design is for maximum safety for the user when handling toxic or hazardous media. It features a

1/8" FNPT port located on the spring housing. The user can easily tube this vent to a safe location. This option can be

incorporated into a self-relieving regulator that provides an additional port to permit the safe expulsion of hazardous

media.

Panel Mount

The panel mount feature requires a panel cut out of 1-1/2", complete with a threaded spring housing, and a panel

mount ring to secure the regulator.

*Self Relieving

The self relieving option is used for internal venting of downstream pressure. From a practical stand-

point, it allows for immediate reduction in pressure setpoints and automatically alleviates regulator lock up.