beautypg.com

4 sms control examples, Sms control examples – Robustel M1000 Pro V2 User Guide User Manual

Page 66

background image

Robustel GoRugged M1000 Pro V2 User Guide


RT_UG_M1000 Pro V2_v.2.0.0

19.11.2013

65 / 69

Confidential

e.g. 3132 means "12",
heartbeatReqLen is 2

1021

heartbeatAckLen

cmd,value

value: 0 - 32

1022

heartbeatAckContent

cmd,value

value:
hex format string.[0-9,a-f], max
length 64
heartbeatAckLen is half of the length
of heartbeatAckContent.
e.g. 3132 means "12",
heartbeatAckLen is 2

1033

logoutEnable

cmd,flag

flag: 0 - disable,1 - enable

1034

logoutReqLen

cmd,value

value: 0 - 32

1035

logoutReqContent

cmd,value

value:
hex format string.[0-9,a-f], max
length 64
logoutReqLen is half of the length of
logoutReqContent.
e.g. 3132 means "12",
logoutReqLen is 2

1036

logoutAckLen

cmd,value

value: 0 - 32

1037

logoutAckContent

cmd,value

value:
hex format string.[0-9,a-f], max
length 64
logoutAckLen is half of the length of
logoutAckContent.
e.g. 3132 means "12",
logoutAckLen is 2

5.2.4 SMS Control examples

Command SMS configuration examples
Configuration
Category

Configuration Description

SMS Content

Comments

Enable

Configuration

enableDelimiter1

0109,1

Enable Delimiter1.

enableDelimiter2

0111,0

Disable Delimiter2.

Option

Configuration

parity

0105,1

Be configured as Odd parity.

authTypeSim1

0201,2

SIM1 is configured as PAP
authType.