Robustel M1000 Pro V2 User Guide User Manual
Page 43
Robustel GoRugged M1000 Pro V2 User Guide
RT_UG_M1000 Pro V2_v.2.0.0
19.11.2013
42 / 69
Confidential
Advanced
Item
Description
Default
Custom
Login
Tick to enable.
Some TCP servers required Login Request Packet with follow flow:
A TCP connection begins with the client opening a TCP/IP socket to the server and sending a
Login Request Packet. If the login request is valid, the server responds with a Login
Acknowledge Packet and begins sending Sequenced Data Packets. The connection continues
until the TCP/IP socket is broken.
Login Acknowledge Packet is optional.
Disable
Max
Retries
Login Request Packet
The maximum retries times for sending Login Request Packet to the server with preset time
interval, selecting from 0 to 60.
After maximum retries, gateway will not retry again, and image login successfully.
0
Interval
Time interval between two retries, selecting from 5 to 120 seconds.
60
seconds
REQ
Login Request Packet, written in Hex format, maximum 64 bytes.
Null