beautypg.com

31 configuration -> at over ip, 32 configuration -> phone book, Configuration -> at over ip – Robustel R3000 User Guide User Manual

Page 93: Configuration -> phone book

background image

Robustel GoRugged R3000 User Guide


RT_UG_R3000_v.2.0.0 17.01.2014 92 / 131
Confidential

Retries

and still do not receive correct respond packets from PPPoE client, it will send
“LCP Terminal Request” packet to disconnect the connection between PPPoE
server and PPPoE client. “Max Retries” ranges from 3 to 5 times.

3.31 Configuration -> AT over IP

This section allows users to set the AT over IP parameters.

AT over IP

Item

Description

Default

Enable AT Settings

Tick to enable AT over IP to control cellular module via AT command remotely.

Disable

Protocol

Select from “TCP server” or “UDP”

UDP

Local IP

You can enter the IP address of cellular WAN, Ethernet WAN or Ethernet LAN.
Null stands for all these three IP addresses.

0.0.0.0

Local Port

Enter the local TCP or UDP listening port.

8091

3.32 Configuration -> Phone Book

This section allows users to set the Phone Book parameters.

Phone Book

Item

Description

Default