beautypg.com

Robustel R3000 User Guide User Manual

Page 51

background image

Robustel GoRugged R3000 User Guide


RT_UG_R3000_v.2.0.0 17.01.2014 50 / 131
Confidential

Slave
ID @ Modbus Slave

Enter the ID number of TCP server.

Null

Interval Timeout @
Transparent

Over

Rlink

The serial port will queue the data in the buffer and send the data to the Cellular
WAN/Ethernet WAN when it reaches the Interval Timeout in the field.

10

Attached serial device
type @ Modbus Over
Rlink

Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”.
Modbus RTU slave: router connects to slave device which works under Modbus
RTU protocol.
Modbus ASCⅡ slave: router connects to slave device which works under
Modbus ASCⅡprotocol.

Null

Display all com @ AT
Over COM

Enable to display all virtual com of the module inside the router. Generally,
router will occupy /dev/ttyUSB0 and /dev/ttyUSB2 for dialing up to GPRS.
Note: Enable this function will disable Cellular WAN function.

Disable

COM Name

Show the virtual com name of the module inside.

/dev/tt
yUSB1


 When Select Protocol “Transparent”: