Robustel GoRugged R3000 User Guide


RT_UG_R3000_v.2.0.0 17.01.2014 49 / 131
Confidential

sent as soon it reaches the specified length.
Note: Data will also be sent as specified by the interval timeout or delimiter
settings even when data is not reaching the preset packet length.

Enable Delimiter1/2

When Delimiter 1 is enabled, the serial port will queue the data in the buffer and
send the data to the Cellular WAN/Ethernet WAN when a specific character,
entered in hex format, is received. A second delimiter character may be enabled
and specified in the Delimiter 2 field, so that both characters act as the delimiter
to control when data should be sent.

Disable

Delimiter1/2

(Hex)

@Transparent

Enter the delimiter in Hex.

0

Delimiter

Process

@Transparent

The Delimiter process field determines how the data is handled when a delimiter
is received.
None: Data in the buffer will be transmitted when the delimiter is received; the
data also includes the delimiter characters.
Strip: Data in the buffer is first stripped of the delimiter before being transmitted.

Strip

Local IP @ Modbus

This item will show up When you enable any VPN tunnel of R3000, it means serial
data can be matched to this local IP address and be transmitted or received via
VPN tunnel.
Note: when you do not enable any VPN tunnel, this item will not show up.

0

Local Port @ Modbus

Enter the Local port for Modbus.

0

Attached serial device
type @Modbus

Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”, “Modbus RTU master”
and “Modbus ASCⅡ master”.
Modbus RTU slave: router connects to Modbus slave device which works under
Modbus RTU protocol.
Modbus ASCⅡ slave: router connects to Modbus slave device which works
under Modbus ASCⅡprotocol.
Note: When select “Modbus RTU slave” and “Modbus ASC

slave” protocol,

router is as TCP Server site, user need to enter a local port number in “Local Port
@Modbus” and wait to be connected.
Modbus RTU master: router connects to master device which works under
Modbus RTU protocol.
Modbus ASCⅡ master: router connects to master device which works under
Modbus ASCⅡ protocol.
Note: When select “Modbus RTU master” and “Modbus ASC

master” protocol,

router is as TCP Client site, user need to enter slave address and slave port
number in “
Slave Address @ Modbus Slave ” and “Slave Port @ Modbus Slave”,
and connect to Server site.

Modbu
s RTU
slave

Modbus

Slave

@Modbus

Add the Modbus slaves which will be polled by Modbus master (router). This
section only displayed when you select “Modbus RTU master” or “Modbus ASCⅡ
master” in “Attached serial device type”.

Null

Slave

Address

@

Modbus Slave

This connection is usually used to connect to the Modbus slave devices which as
TCP server. Enter IP address of the TCP server.

Null

Slave Port @ Modbus Enter the port number of TCP server.

Null