Connection Mode
Connection Mode
Select from “Always Online” and “Connect On Demand”.
Always Online: Auto activates PPP and keeps the link up after power on.
Connect On Demand: After selection this option, user could configure
Triggered by Serial Data, Triggered by Periodically Connect and Triggered by
Time Schedule.
Note: If you select several connect on demand polices, router only have to
meet one of them to be triggered.
Connect
On
Demand
Redial Interval
Router will automatically re-dial with this interval when it fails
communicating to peer via TCP or UDP.
30
Max Retries
The maximum retries times for automatically re-connect when router fails
to dial up.
After maximum retries, router will reboot the wireless module. If router still
cannot dial up successfully, it will try to switch to the other SIM card. Then
router will re-connect with the other SIM card with maximum retries.
After successful connection, the Max Retries counter will be set to 0.
3
Inactivity Time
Configurable after “Connect On Demand” was selected.
This field specifies the idle time setting for GPRS/3G auto-disconnection and
trying to revert back to preferred SIM card.
0 means timeless.
0
Serial Output Content
The content which output to the serial device which connect to router and
inform it that router is ready to receive serial data.
Null
Triggered by Serial Data
Tick this check box to allow router automatically connects to cellular
network from idle mode when there is data comes out from serial port.
Enable
Triggered by Tel
Tick this check box to allow router automatically connects to cellular
network from idle mode when make a voice call to router.
Disable
Triggered by SMS
Tick this check box to allow router automatically connects to cellular
network from idle mode when send a specific SMS to router.
Disable
SMS Connect Command
Users shall send this specific SMS to trigger router to connect to cellular
network.
Null
SMS
Disconnect
Command
Users shall send this specific SMS to trigger router to disconnect to cellular
network.
Null
SMS Connect Reply
When router connects to cellular network, it will automatically send out this
SMS to specific users (set in the Phone Group).
Null
SMS Disconnect Reply
When router disconnect from cellular network, it will automatically send out
this SMS to specific users (set in the Phone Group).
Null
Phone Group
Click to add Phone Group to Set specific users’ phone Book and which
phone Group they are belonged to.
Null
Triggered by IO
Tick this check box to allow router automatically connects to cellular
network from idle mode when there is a DI (DI_1) alarm input.
Disable
Periodically Connect
Tick this check box to allow router automatically connects to cellular
network with preset interval which you preset in Periodically Connect
Interval.
Enable