Enable DI

Click to Enable DI.

Disable

Mode

Select from “OFF”, “ON”, “EVENT_COUNTER”.
OFF: Connect to GND (logic 0). When pin DI connects to GND, R3000 will
detect there is a DI alarm input.
ON: Open from GND (logic 1). When pin DI does not connect to GND, R3000
will detect there is a DI alarm input.
EVENT_COUNTER: under event counter mode.

OFF

Filtering

Software filtering is used to control switch bounces.
Input from 0 to 10000ms.

1

Count Trigger

Available when DI under Event Counter mode.
Input from 0 to 100. (0=will not trigger alarm)
It will trigger alarm when counter reaches this figure. After triggering alarm, DI
will keep counting but not trigger alarm again.

0

Counter Active

Available when DI under Event Counter mode.
Select from “Hi to Lo”, “Lo to Hi”.
In Event Counter mode, the channel accepts limit or proximity switches and
counts events according to the ON/OFF status. When “Lo to Hi” is selected,
the counter value increases when the attached switch is pushed. When “Hi to
Lo” is selected, the counter value increases when the switch is pushed and
released.

Lo to Hi

Counter

Start

When

Power On

Available when DI under Event Counter mode.
Start counting as soon as possible on the modem when enable this option.
When R3000 need to work under Event Counter mode, user shall enable
“Counter Start When Power On”.
If “Counter Start When Power On” is disabled, it will also start counting when
receiving SMS command. Refer to another document SMS command of
R3000
.

Disable

Triggering Alarm

The SMS to receive upon triggering alarm. (70 ASIC II char max)

Null

Recovering Alarm

The SMS to receive upon recovering alarm. (70 ASIC II char max)

Null

Phone Group

The alarm SMS will send to specified phone group.
Each phone group include up to 10 phone numbers.

Null