g. Connect to receptacle on adapter as follows:
1. Open cover (J).
2. Push in lock button (K), and pull handle (L)
halfway up to “open position”.
3. Remove hydraulic quick coupler (H) from
storage plate on combine, and clean mating
surface of coupler.
4. Position coupler onto adapter receptacle (M),
and push handle (L) to engage pins into
receptacle.
5. Push handle (L) to “closed position” until lock
button (K) snaps out.
h. Attach combine electrical connector (N) to
adapter as follows:
1. Remove cover on adapter electrical
receptacle (O).
2. Remove connector (N) from combine.
3. Align lugs on connector (N) with slots in
adapter receptacle (O), and push connector
onto receptacle. Turn collar on connector to
lock it in place.
i.
Rotate disc (P) on adapter driveline storage hook,
and remove driveline from hook.
j.
Pull back collar on end of driveline, and push onto
combine output shaft (Q) until collar locks.
k. Disengage both adapter float locks by moving
latch (T) away from adapter, and moving lever (U)
at each lock to “lowest position”.