Maintenance/service – MacDon 871 Combine Adapter User Manual

Page 23

background image

23

MAINTENANCE/SERVICE

HYDRAULIC SYSTEM (continued)

Flow Control Relief Pressure
A possible cause of insufficient draper speed is
low relief pressure.
To check relief pressure:
1. Attach a 5000 psi (34.5 MPa) pressure gauge

in gauge port (GP) of valve block.

2. Install a needle valve between orange colour

coded male coupler on adapter and orange
colour coded female coupler on header.

3. Set flow control knob to number 6 on dial.
4. Run combine engine at operating speed.
5. Engage header drive.
6. Close needle valve until flow stops. Pressure

reading should be 2850 psi (19.7 MPa).

WARNING: To avoid bodily injury
from bursting hoses and/or
exploding components, do not

exceed 3100 psi pressure (21.4 MPa). Do not
continue closing needle valve if pressure
exceeds 3100 psi (21.4 MPa).

If relief pressure requires adjustment:
1. Loosen jam nut (C).
2. Turn relief screw until relief pressure is correct.
3. Tighten jam nut.

FLOW CONTROL RELIEF ADJUSTMENT

GP

C

COMBINE ADAPTER HYDRAULIC SCHEMATIC