6.1 Electrical specifications

Voltage requirement 9-33V DC unregulated,

less than 1Vp-pripple

Power consumption

max.4.5 Watt.

6.2 Optical specifications

Light source

670 nm visible laser diode

Deflection system

rotating polygon
(10 facets)

Scan rate

1000 scans/sec

Decode rate

max. 1000 decodes/sec

Spot velocity

215 m/sec at 100 mm

Reading width

max. 140mm at 100mm
max. 300mm at 300mm

Min. resolution
at PCS 0,9

0.127 mm (5 mil)

Min PCS values

0.30

Depth of field

max. 750 mm

at PCS 0.9

(resolution=1mm)