1 transformer wiring, 4 . 2 . 1 transformer wiring – MTS Model 506-62-72 Hydraulic Power Supply User Manual
Page 32

4-4 Installation
4 . 2 . 1
Transformer Wiring
One of two types of transformers is installed in the starter assembly.
Check the wiring configuration of the transformer before applying ac
power to the HPS.
Standard transformer
wiring
This figure shows the jumper wiring required on a standard transformer
for source voltages of 460 and 230 Vac.
jumper
H1
X2
H2
X1
H3
460 Vac
H4
H1
X2
H2
X1
H3
230 Vac
H4
VW-C036
jumper
jumper
Figure 4-4. Standard Transformer Wiring Configuration
Optional transformer
wiring
An optional multi-tap transformer may be used for source voltages other
than 230 Vac and 460 Vac. The following figure shows the typical
wiring required for various voltages. Source voltages are applied to
terminals H1 through H5 as shown. An output voltage is tapped from
terminals X1 through X4. Check the output voltage with a voltmeter.
It should be 110 Vac for systems using 50 Hz power and 115 to 120 Vac for
systems with 60 Hz.
X4
VW-C037
X3
X2
X1
H4
H5
H3
H2
H1
208/220/230/240 Vac
380/400/416 Vac
440/460/480 Vac
500/550/575/600 Vac
110/120/125/130 Vac
100/110/115/120 Vac
85/91/99 Vac
Figure 4-5. Typical Multi-Tap Transformer Wiring Configuration