Table 3-1. Maintenance Schedule

Procedure

Interval

Subsection

Check output pressure on gage*

daily

Replace high-pressure filter

when the indicator points to CHANGE

3.1.1

Replace low-pressure filter

when Dirty Filter indicator lights

3.1.1

Check hydraulic fluid level on gage

daily

3.1.2

Check hydraulic fluid in reservoir

150 operating hours

3.1.2

Analyze hydraulic fluid

500 operating hours

3.1.2

Check accumulator precharge

at established interval

3.1.3

Check hydraulic hoses

monthly

*

See Subsection 3.2.1 to adjust the output pressure.

3 . 1 . 1

Filters

Fluid filtration is provided by a 10-micron high-pressure filter and a
3-micron low-pressure filter. See Figure 3-1 for the location of the
filters and their drains.

WARNING

!

High-pressure release occurs if the system is pressurized.

High-pressure release may cause personal injury or damage equipment.

Ensure that the output pressure gage reads zero before replacing the
filters.

3 . 1 . 1 . 1 High-Pressure Filter Replacement

CHANGE

OK

DIRT ALARM

VW-GO46

Replace the high-pressure filter elements whenever the DIRT ALARM
indicator mounted on the base of each high-pressure filter housing
points to CHANGE (red or yellow zone) or whenever the hydraulic
fluid is replaced.

1.

Press Stop on the HPS. The output pressure gage must read zero.