Stile, Installation of panel – Metal Sales Stile Installation User Manual
Page 28
STILE
27
© Metal Sales Manufacturing Corporation/ Subject to change without notice
INSTALLATION OF PANEL
(CONT)
1. Stile panels are available in lengths from 3'-0" to 20'-0" in one foot increments. For runs longer
than 20'-0", panels are designed to endlap.
2. Endlaps can be placed staggered or in-line with the previous panel endlap. Either method of
installation is suitable, but in-line endlapping tends to be easier to order and install.
3. Follow the panel installation sequence as shown below. Regardless of which method you use,
install panels from right to left, lapping the ridge panel over the eave panel.
4. Fasten panels with a Woodscrew XL fastener at every other valley and every third step of the
panel (see page 25). Fasten at the endlap in every valley just below the step in the panel.
ENDLAPPING OF PANEL
IN-LINE ENDLAPPING
7
3
6
4
2
1
8
7
5
3
PANEL INSTALLATION DIRECTION
PANEL INSTALLATION DIRECTION
EAVE
RIDGE
In a staggered endlap example a 28'-0" run
would be covered with panel lengths of 15'-0"
and 13'-0" alternating right to left.
In an in-line endlap example a 28'-0" run
would be covered with 14'-0" panels at both
the top and the bottom of the run.
8
4
1
5
2
6
STAGGERED ENDLAPPING
WOODSCREW XL
SEALANT
ENDLAP
FASTENING PATTERN AT ENDLAP
WOODSCREW XL
STILE PANEL