Setting – Memmert ICH 256 Climate Chambers (Generation 2003) User Manual
Page 55

55
Advanced Functions
Setting:
Setting:
Overtemperature protection:
Adjustment range: up to max. 10 °C above nominal temperature
(for details of the nominal temperature, see nameplate)
Setting:
1. Select the
MAX
icon with the push-turn control.
2. Hold down the SET key and set the desired temperature limit
with the push-turn control (e.g. to 38.5 °C).
°C
MIN
AUTO
MAX
Undertemperature protection:
Adjustment range: 10 °C below the minimum temperature of
the appliance up to 10 °C above nominal temperature of the
appliance (for details of the nominal temperature, see nameplate).
The lower alarm limit value cannot be set higher than the top
one. If no undertemperature protection limit is required, set
the lowest temperature.
°C
MIN
AUTO
MAX