22 shaftstartposition, 23 toolcontrol – Lenze E94AxHE Technology Application Synchronism User Manual
Page 72
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
72
L
EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.22
ShaftStartPosition
4.14.23
ToolControl
C03983
DIS:bPosTeach
• Display of input signal bPosTeach.
0 FALSE
1 TRUE
C03984
DIS:bBusy
• Display of output signal bBusy.
0 Profile parameters are available.
1 Conversion active, no access to
profile parameters at the moment.
C03985
-2147483647
2147483647 Status
• Display of the bit-coded output
signal dnState.
Parameter
Possible settings
Information
Is an instance of
Function
L_SdSetPosition
Conversion of the master shaft starting position selected in the real units of the
machine via C03034 into a position in [increments].
Parameter
Possible settings
Information
C03034
-214000.0000
unit
214000.0000 Position value
• Initialisation: 0.0000 unit
C03035
String of digits
Position unit
• Read only
C03036
-2147483647
2147483647 Status
• Read only
Is an instance of
Function
L_LdToolControl
Parameter
Possible settings
Information
C03825
-2147483647
2147483647 Status
• Display of the bit-coded output
signal dnState.
C03826/1
String of digits
Position unit
• Read only
C03826/2
String of digits
Speed unit
• Read only
C03827
-214748.3647
unit/t
214748.3647 Reference speed
• Read only
• Reference value for selecting
speeds.
C03830
-2147483647
unit/t
2147483647 Correction speed at the input
• Read only
• Is generated from the speed
signal dnTpMakeUpLeeway_s.