13 application error messages, Application error messages – Lenze E94AxHE Technology Application Synchronism User Manual
Page 53
![background image](/manuals/566324/53/background.png)
EDS94TA10040xxxx EN 1.1 - 10/2008
L
53
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Application error messages
4.13
Application error messages
For the output of application-specific error messages, an FB instance ApplicationError of
the function block L_DevApplErr is available.
r
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
r
The first four inputs can be connected to the multiplexer parameters with the desired
tripping signals. The next four inputs are firmly connected to the tripping signals of the
application.
r
Parameter setting: Tab All parameters
Error message
Error ID
Error response
1
Free (configurable via C03060/1)
8001
Error
2
Free (configurable via C03060/2)
8002
Error
3
Free (configurable via C03060/3)
8003
Error
4
Activate Modulo mode
8004
Warning
5
Following error
8005
Warning
6
Drive cannot follow
8006
No response
7
Drive system interrupted
8007
Quick stop by trouble
8
Reserved
8008
Warning
Parameter
Lenze setting
C05900
Module ID
999
C05901/1...8
Error ID 1 ... 8
See table above
C05902/1...8
Error response 1 ... 8
See table above
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Application fault 1
C03060/1
FALSE Application fault 2
C03060/2
FALSE Application fault 3
C03060/3