EDS94TA10040xxxx EN 1.1 - 10/2008

L

53

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Application error messages

4.13

Application error messages

For the output of application-specific error messages, an FB instance ApplicationError of

the function block L_DevApplErr is available.

r

Via the 8 boolean inputs up to 8 different application error messages with

parameterisable module ID, error ID and error response can be activated by the

application.

r

The first four inputs can be connected to the multiplexer parameters with the desired

tripping signals. The next four inputs are firmly connected to the tripping signals of the

application.

r

Parameter setting: Tab All parameters

Error message

Error ID

Error response

1

Free (configurable via C03060/1)

8001

Error

2

Free (configurable via C03060/2)

8002

Error

3

Free (configurable via C03060/3)

8003

Error

4

Activate Modulo mode

8004

Warning

5

Following error

8005

Warning

6

Drive cannot follow

8006

No response

7

Drive system interrupted

8007

Quick stop by trouble

8

Reserved

8008

Warning

Parameter

Lenze setting

C05900

Module ID

999

C05901/1...8

Error ID 1 ... 8

See table above

C05902/1...8

Error response 1 ... 8

See table above

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE Application fault 1

C03060/1

FALSE Application fault 2

C03060/2

FALSE Application fault 3

C03060/3