beautypg.com

1 basic signal flow – Lenze E94AxHE Technology Application Synchronism User Manual

Page 22

background image

9400 Technology applications | Synchronism with mark synchronisation

Parameter setting & configuration

Basic signal flow

22

L

EDS94TA10040xxxx EN 1.1 - 10/2008

4.1

Basic signal flow

[4-1]

Signal flow of the TA "Synchronism" (schematic diagram)

Functions in the "Synchronism" operating mode

Master value processing

Mark synchronisation (master value)

Virtual clutch

Master value adjustment

Setpoint processing

Mark synchronisation (setpoint)

Basic drive functions

Homing

Manual jog (inching)

Position override function

!

Quick stop

"

Limiter (optional)

#

Brake control (optional)

v

t

Dj

3

M

0

v

2

4

Slave

LS_ManualJog

n

t

и

з

n

t

LS_Positioner

0

-100

100 200

LS_Homing

6

7

8

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

9

:

;

Real master/

Virtual master

Dj

Dj

1

5

TP