beautypg.com

7 object dictionary – JUMO 902910 CANtrans T RTD Temperature Probe with CANopen Output Operating Instructions User Manual

Page 26

background image

26

7 Object dictionary

0x1800

-

PDO 1
Communica-
tion
Parameter

Controls the transmis-
sion conditions for 1st
PDO

0x01

UINT32 RW

1

COB-ID

ID with which the PDO
is transmitted

0x180 — 0x57F
bit 0x800000000
set = PDO inactive

ex-factory:
0x180+Node-ID

0x02

UINT8

RW

1

Transmission
Type

Transmission mode

0x01 = synchronous
0xFF = event-

controlled

ex-factory: 0xFF

0x03

UINT16 RW

1

Inhibit Time

Do not transmit before
time has elapsed

0 — 65535
(x 0.1 msec)

ex-factory:
0 = inactive

0x05

UINT16 RW

1

Event Time

Time for cyclic
transmission

0 — 65535 msec

0 = inactive

ex-factory:
1000 msec

0x1804 -

PDO 5
Communica-
tion
Parameter

Controls the transmis-
sion conditions for 2nd
PDO (on devices with 2
sensors)

0x1F80 -

UINT32 RW

NMT Startup

Bootmode ➩ Chapter
5.2 “NMT”, page 15

0xC "Preopera-
tional"
0x8 "Operational"

Ex-factory: 0xC

0x2000 -

UINT8

RW

1

Node-ID

Setting the node
address via SDO
(also possible via LSS)

1 — 127
ex-factory: 123 (PT)
ex-factory: 124 (P)
ex-factory: 125 (T)
ex-factory: 126 (TT)

0x2001 -

UINT8

RW

1

Baud rate

Setting the baud rate
via SDO
(also possible via LSS)

0 = 1 Mbaud
1 = 800 kbaud
2 = 500 kbaud
3 = 250 kbaud
99 = 200 kbaud
4 = 125 kbaud
98 = 100 kbaud
6 = 50 kbaud
7 = 20 kbaud

ex-factory: 2