B: gas type dependence, Conversion table, Indication range above 10 – INFICON BPG400 ATM to Ultra-High Vacuum Gauge User Manual
Page 55: Mbar

tina03e1-b (2004-02) BPG400 v1.om
55
Output signal U
[V]
[mbar]
Pressure p
[Torr]
[Pa]
0.3 / 0.5
Sensor error (
→ 49)
0.51 … 0.774
Inadmissible range
0.774
5Ч10
-10
3.75Ч10
-10
5Ч10
-8
1.00
1Ч10
-9
7.5Ч10
-10
1Ч10
-7
1.75
1Ч10
-8
7.5Ч10
-9
1Ч10
-6
2.5
1Ч10
-7
7.5Ч10
-8
1Ч10
-5
3.25
1Ч10
-6
7.5Ч10
-7
1Ч10
-4
4.00
1Ч10
-5
7.5Ч10
-6
1Ч10
-3
4.75
1Ч10
-4
7.5Ч10
-5
1Ч10
-2
5.50
1Ч10
-3
7.5Ч10
-4
1Ч10
-1
6.25
1Ч10
-2
7.5Ч10
-3
1Ч10
0
7.00
1Ч10
-1
7.5Ч10
-2
1Ч10
1
7.75
1Ч10
0
7.5Ч10
-1
1Ч10
2
8.50
1Ч10
1
7.5Ч10
0
1Ч10
3
9.25
1Ч10
2
7.5Ч10
1
1Ч10
4
10.00
1Ч10
3
7.5Ч10
2
1Ч10
5
>10.00
Inadmissible range
Pressure indicated (gauge adjusted for air, Pirani-only mode)
10
2
8
6
4
2
10
1
8
6
4
2
10
0
8
6
4
2
10
–1
8
6
4
2
10
–2
8
6
4
2
10
–3
p (mbar)
p
eff
(mbar)
10
–3
2
4 6
10
–2
2
4 6
10
–1
2
4 6
10
0
2
4 6
10
1
2
4 6
10
2
H
2
He Ne
Xe
Ar
Freon 12
H
2
O
vapor
Air
O2
CO
N2
Kr
Indication range
above 10
-2
mbar)
CO
2
Conversion table
B: Gas Type Dependence
Indication range
above 10
-2
mbar
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- I/O1000 I/O module (18 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)