5 i&m identification & maintenance functions, 1 i&m0 – INFICON PSG55x ATM to Medium Vacuum Gauge (Profibus) User Manual
Page 21

tira56e1 (2010-02) PxG55x.cp
21
5 I&M Identification & Maintenance Functions
I&M is a concept for manufacturer- and sector-independent standardized identi-
fication of field devices. The field device provides specific information in an elec-
tronic nameplate, which can be primarily accessed online with initial operation and
maintenance.
The reading and writing is made on an I&M parameter block consisting of
64 octets. (
→ [4])
Content
Octets
Coding (H)
Header
Manufacturer specific
10
00
H
I&M Block
MANUFACTURER_ID 2
0x017A
H
= INFICON
ORDER_ID 20
Ordering
no.
SERIAL_NUMBER 16
Serial
no.
HARDWARE_REVISION 2
Hardware
revision
1)
SOFTWARE_REVISION 4
Software
revision
1)
REVISION_COUNTER 2
Revision
counter
PROFILE_ID 2
5A00
H
PROFILE_SPECIFIC_TYPE 2
0000
H
IM_VERSION 2
0101
H
IM_SUPPORTED 2
0000
H
1)
of the Profibus board
5.1 I&M0