beautypg.com

Programming enables – HYDAC ETS 3000 User Manual

Page 34

background image

ETS 3000 User Manual

05 Sep 2008

10

8. Programming

Enables


The unit has 2 program enables which must both enabled in order for the settings to be
modified. The operating program enable can be set or cancelled during operation. It provides
protection against inadvertent changes to the unit's settings. Program disable via main
programming enable prevents any changes being made to the settings during operation. This
serves, for example, as a safety function or as a protection against unauthorized alterations.

8.1

Changing the Operating Program Enable


3 s

Operating mode

3 s

Press both arrow keys
at the same time and
hold them down

Change setting using

Loc

FrEE

= programming disabled

= programming enabled

Display
(Release the
arrow keys.)

2 s

SP1

SP2

HYDAC

mode

°C

*

SP1

SP2

HYDAC

mode

*

°C

*

*

°C

°C

or

or press the "mode" key

for 3 s.


8.2

Changing the Main Programming Enable


Switch off the supply voltage or disconnect the unit from the supply voltage.

Press both arrow keys
at the same time and
hold them down.
Switch on the supply

down for 3 s.)

voltage. (Hold keys

3 s

Operating mode

3 s

Change setting using

Loc

FrEE

= programming disabled

= programming enabled

Display
(Release the
arrow keys.)

2 s

SP1

SP2

HYDAC

mode

*

SP1

SP2

HYDAC

mode

*

°C

*

*

°C

°C

or

or press the "mode" key


Note:

• If any settings have been changed, PRoG appears briefly in the display when the display

switches over. The new setting has then been saved in the unit.