HYDAC ETS 3000 User Manual
Page 33

ETS 3000 User Manual
05 Sep 2008
9
Setting Display
Setting
range
Initial
(default)
setting
Display filter (Display)
Display reacts slowly to temperature
fluctuations
Display reacts normally to temperature
fluctuations
Display reacts quickly to temperature
fluctuations
SLOW/
MEDI/
FAST
MEDI
Setting the indication range (RANGE)
The temperature is shown in °C.
The temperature is shown in °F.
When switching between °C and °F the ETS 3000
automatically converts the switching settings to the newly
selected scale.
°C/
°F
°C
Analogue output (Output):
The analogue output supplies a
4–20 mA signal
The analogue output supplies a
0–10 V signal
MAMP/
VOLT
MAMP
Version number (Version)
Displays the current software version. (View only)
To exit the Basic Settings menu (End)
Closes the Basic Settings menu.
Further changes can be made to the
basic
settings.
YES/ NO
NO
If any basic settings have been changed, PRoG appears briefly in the display as soon as the Basic Settings menu
is closed, and then the value selected for primary display is shown.