ENS 3000 WITH TEMPERATURE SENSOR

Input data:

ENS 3000

Fluid level sensor:

Sensor type

capacitive fluid level sensor

Probe length

9.80, 16.20, 20.50, 28.40 inch

Active zone

6.70, 10.25, 14.15, 23.20 inch

Inactive zone

3.10, 5.95, 6.35, 5.20 inch

Max. speed of change
in fluid level

9.80 inch: 1.57 inch/s;

16.20 inch: 2.36 inch/s;

20.50 inch: 3.15 inch/s;

28.40 inch: 3.94 inch/s

Repeatability

≤ 2% FS

Switching point accuracy

≤ 2% FS

Temperature:

Sensor type

Semi-conductor temperature sensor

Measuring range

-13 .. + 212 °F

Accuracy

± 34.7 °F

Reaction speed (T

90

) 180s

Outputs:

Analogue output (optional)

With 1 or 2 SP: user selectable
0 .. 10 V (ohmic resistance min.1 kΩ) or
4 .. 20 mA (ohmic resistance max. 500 Ω)
With 4 SP:
0 .. 10 V (ohmic resistance min.1 kΩ)
corresponds to measuring range

Switching output

1 or 2 or 4

Type PNP

transistor

output

Programmable as N/O or N/C

Assignment of switching output

Temperature or fluid level (user selectable)

Switching current

1 or 2 SP: max. 1.2 A each
4 SP:

max. 0.25 A each

Switching cycles

> 100 million

Ambient conditions:

Ambient temperature

32 .. +140 °F

Operating temperature range

32 .. +140 °F

Storage temperature range

-40 .. +176 °F

Fluid temperature range

32 .. +140 °F **

- mark

EN 61000-6-1/ 2/ 3/ 4

Vibration resistance

approx. 5 g

Shock resistance

approx. 25 g

Other data:

Max. tank pressure

7 psi short-term 40 psi (t < 1 min)

Supply voltage

18 .. 35 V with analogue output
9 .. 35 V without analogue output

Type of protection

IP 67

Fluids

Hydraulic oils (mineral based),
synthetic oils, fluids containing water ***

Components in contact with the fluid

ceramic

Display

4 digit, 7-segment LED, red,
height of digits 0.28 inch

Supply voltage residual ripple

≤ 5 %

Protection against reverse polarity of the
supply voltage, excess voltage, override,
and short-circuit protection

provided

FS

= Full Scale = relative to the full measuring range

*

specified for calm, non-turbulent fluid

**

larger temperature range on request

***

other fluids on request