Setting Display

Settings
available

Default
setting

Setting the type of fluid

Fluid level sensor calibrated to oil

parameters

oil/ AcL

oil

Fluid level sensor calibrated to

cooling lubricant parameters

(Aqueous cooling Lubricants

≙ AcL)

When the new selection is saved, the change is active. On the version
with 4 SP the message

is also displayed.

Assigning the analogue output (Select Output)*

Assigns the analogue
output to fluid level.

niv/
TEMP

niv

Assigns the analogue
output to temperature.

Analogue output (Output)

The analogue output supplies a
4 .. 20 mA signal

MAMP/
VOLT

MAMP

The analogue output supplies a
0 .. 10 V signal

Re-setting the measuring probe to factory settings**

The factory settings are not

active

YES/ NO NO

The factory settings are active

When the new selection is saved, the message

is displayed and the

change is active.
Version number (Version)
Displays the current software version
(view only)

To exit the "Basic settings" menu (End)

Closes the "Basic settings"
menu.

YES/ NO NO

Basic settings can continue to
be processed.

If any basic settings have been altered, "ProG" appears briefly in the
display as soon as the basic settings menu is closed and then the value
selected for primary display is shown.

* This menu point appears only on versions with 1 or 2 SP.
** This menu point appears only on versions with 4 SP.