HYDAC ENS 3000 User Manual
Page 16
![background image](/manuals/562192/16/background.png)
E
16
Setting Display
Settings
available
Default
setting
Setting the type of fluid
Fluid level sensor calibrated to oil
parameters
oil/ AcL
oil
Fluid level sensor calibrated to
cooling lubricant parameters
(Aqueous cooling Lubricants
≙ AcL)
When the new selection is saved, the change is active. On the version
with 4 SP the message
is also displayed.
Assigning the analogue output (Select Output)*
Assigns the analogue
output to fluid level.
niv/
TEMP
niv
Assigns the analogue
output to temperature.
Analogue output (Output)
The analogue output supplies a
4 .. 20 mA signal
MAMP/
VOLT
MAMP
The analogue output supplies a
0 .. 10 V signal
Re-setting the measuring probe to factory settings**
The factory settings are not
active
YES/ NO NO
The factory settings are active
When the new selection is saved, the message
is displayed and the
change is active.
Version number (Version)
Displays the current software version
(view only)
To exit the "Basic settings" menu (End)
Closes the "Basic settings"
menu.
YES/ NO NO
Basic settings can continue to
be processed.
If any basic settings have been altered, "ProG" appears briefly in the
display as soon as the basic settings menu is closed and then the value
selected for primary display is shown.
* This menu point appears only on versions with 1 or 2 SP.
** This menu point appears only on versions with 4 SP.