Fdx2000 vs. fdx3000 dimmer curve comparison – ETC CEM3 v1.5.1 User Manual
Page 65
![background image](/manuals/559281/65/background.png)
D
FDX 3000 Dimmer Racks
59
FDX2000 vs. FDX3000 Dimmer Curve Comparison
Curves in FDX3000 reference voltage rather than power. Therefore the following table will
help to show the correlation between FDX2000 curve names and FDX3000 curve names.
.
FDX2000 Curve
English / German
FDX3000 Curve
English
Comment
1 = Linear (default)
Square
proportional to RMS power output (FDX2000 Linear)
2 = Stage1
Stage 1
Built to match an old Siemens curve
3 = Stage2
Stage 2
Built to match an old Siemens curve
4 = Log
Linear
proportional to RMS voltage output
5 = Fluor1
Fluor 1
6 = Fluor2
Fluor 2
7 = Pow/2
n.a.
obsolete
8 = 10%
n.a.
obsolete
9 = VIP90
VIP
10 = ANDI
ANDI
n.a
Mod-Square (Default)
n.a
Mod-Linear
n.a
Sensor 2.0
older mod square law