Automatic Control

Typically, in a redundant tracking system, the switch should be left in the auto position.

When the switch is set to auto, the A processor will have control by default. Control will

switch to B when any of the following events occur.

Loss of network

If network connectivity is lost to one processor but not the other, control will switch to the

one which still has network connectivity.

Loss of DMX

If DMX is lost by one processor but not the other, control will switch to the one still able to

receive DMX (note that the DMX data line is interconnected between both, so this would

only occur in the event of the failure of a DMX transceiver on the processor itself).

Power errors

If one processor experiences power errors but the other does not, control will switch to the

one that does not. Again, note that the same power is connected to both processors so this

would only occur in the event of an internal failure in the processor.

Total processor loss

If communication is completely lost to one processor but not the other, then control will

switch to the processor which is still available.

Display Status

When tracking is active and the A processor is in control, the displays will show as follows:

When control switches to the B processor (either by automatic failover or manual control

using the switch), the displays change to the following:

Rack 1 - CEM3 Rack
System OK

DMXA: 1

DMXB: Off

sACN: 2/1

[Info]

CEM3 Control

Backup Ready

Processor A

Processor B