1

Getting Started

7

Performing a Quick Setup

Quick Setup is used to set up your rack using a minimum amount of data to achieve a basic

configuration.

You can begin a quick setup by navigating to [Setup]>Quick Setup>[Enter].

From this interface you can use the CEM3 interface to enter data in up to four fields to

quickly establish your rack configuration: Rack Number, First Circuit, Numbering, and

Dimmer Double (see below for field descriptions).

Once you have entered data in the desired fields, select [Go] and press [Enter] to save the

setup changes.

Rack Number

Enter a reference number between 1-999 to identify the rack. Default is 1.

First Circuit

Enter the desired number for the first circuit in the rack. If this is your first or only rack, this

number is typically 1. If this rack is one of many in your system, this number typically

continues the numbering sequence from the previous rack. Default is 1.

Numbering

Choose between “Straight” or “Balanced”. “Straight” results in circuit numbering that will

proceed sequentially straight through the entire rack. See

Straight (rack numbering), page

16

for more information.

“Balanced” results in circuit numbering that will distribute the circuits evenly across the

different power phases so that neighboring circuits do not place an uneven load on any

phase. See

Balanced (rack numbering), page 10

for more information.

Default for Sensor3 installed racks (SR3)is “Balanced”. Default for Sensor3 portable racks

(SP3) is “Straight.”

Dimmer Double

Choose between “Yes” and “No” to activate or deactivate dimmer doubling for the rack.

Default is “No” (see

Dimmer Doubling (UL/ 120V 60 Hz systems only), page 11

).

N o t e :

Prior to performing a Quick Setup, make sure that your rack DIP switch settings

are set appropriately for your rack type. See

Setting Rack DIP Switches and

Termination, page 40

for more information.

C A U T I O N :

Quick rack setup will overwrite some of the data in your rack. Only perform a quick

setup when you wish to reconfigure your system or are instructed to do so by ETC

Technical Services.