Panic fade diagram, Level time panic activated panic deactivated – ETC CEM3 v1.5.1 User Manual
Page 42
36
CEM3 User Manual
•
Out Delay (sec) - This setting determines the length of time (in seconds) for the Panic
look to delay before deactivating (default is 0).
•
Fade In (sec) - This setting determines the length of time (in seconds) for the Panic look
to fade in when activated (default is 2).
•
Fade Out (sec) - This setting determines the length of time (in seconds) for the Panic
look to fade out when deactivated (default is 2).
•
Shed Other Loads - This Yes/No setting determines if active levels at the moment of
the Panic trigger should remain active or be forced off. Default is “N” (No).
The following graphic illustrates how these settings affect panic function:
Level
Time
Panic
Activated
Panic
DeActivated
In Delay
0-360s
Fade In
0-360s
Out Delay
0-360s
Fade Out
0-360s
Steady State
until contact changes
Indicator turns on
Indicator turns off
Panic Levels
Off
Panic Fade Diagram