beautypg.com

ETC Unison DRd Pedestal Installation Setup Guide User Manual

E t c, Unison, Drd pedestal installation

background image

E T C

®

S e t u p G u i d e

Unison

®

DRd Pedestal Installation

Unison DRd Pedestal Setup Guide

Page 1 of 1

Electronic Theatre Controls, Inc.

Corporate Headquarters

„

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

„

Tel +608 831 4116

„

Fax +608 836 1736

London, UK

„

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

„

Tel +44 (0)20 8896 1000

„

Fax +44 (0)20 8896 2000

Rome, IT

„

Via Ennio Quirino Visconti, 11, 00193 Rome, Italy

„

Tel +39 (06) 32 111 683

„

Fax +44 (0)20 8896 2000

Holzkirchen, DE

„

Ohmstrasse 3, 83607 Holzkirchen, Germany

„

Tel +49 (80 24) 47 00-0

„

Fax +49 (80 24) 47 00-3 00

Hong Kong

„

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

„

Tel +852 2799 1220

„

Fax +852 2799 9325

Service: (Americas)

[email protected]

„

(UK)

[email protected]

„

(DE)

[email protected]

„

(Asia)

[email protected]

Web:

www.etcconnect.com

„

Copyright © 2008 ETC. All Rights Reserved.

„

Product information and specifications subject to change.

7183M2230

„

Rev A

„

Released 09/2008

Mounting a DRd Enclosure on a Pedestal

Step 3:

Remove the eight screws and washers that secure the front panel to the pedestal unit.

Step 7:

Position the DRd enclosure on the floor stand pedestal and align with the mounting holes
provided.

Step 8:

Bolt the rack into place.

Step 9:

Reinstall the front panel to the pedestal unit, replacing all hardware removed in step 3.

The Unison DRd pedestal is designed with the same footprint as the Unison DRd
enclosure. Conduit access in the bottom of the DRd overlaps the floor stand access
panel for contractor wiring and installation convenience. It is recommended to secure a
DRd enclosure installed on a pedestal to a wall for greater stability.

432mm

17”

186.7mm

7.35”

35.5mm

1.4”

35.5mm

1.4”

Step 1:

Use the measured dimensions in the graphic

(left) to mark the hole locations for the floor

mounting hardware.

Step 2:

Drill holes for floor mounting hardware.

Step 4:

Position the pedestal on the floor hardware
previously placed for marking the holes.

Step 5:

Secure the pedestal base to the floor.

Step 6:

Create conduit access in the bottom of the DRd
enclosure. Notice the label inside the bottom of
the DRd indicating the recommended locations
for conduit access. Do not create conduit
access outside of the recommended locations.

Table of contents