beautypg.com

ETC Source Four Dimmer Installation Guide User Manual

Installation guide, Overview, Prepare for installation

background image

D i m m e r

Installation Guide

Overview

The Source Four Dimmer is a universal voltage input, single dimmer that can be field installed to an existing

Source Four fixture.
The Source Four Dimmer provides a simple user interface for local manual control, allowing setting of the DMX

address and setting a manual level. In addition the DMX In and Thru connectors allow control, RDM discovery

and configuration. RDM configuration includes setting the DMX start address, selecting the output curve, and

receiving status and feedback from the dimmer.

Three kit models are available including:

CAUTION: Do not install the Source Four dimmer

positioned above a fixture that is in a

yoke out position. Dimmer overtemp and

shutdown may occur.

Source Four Dimmer Kit

Mounts to Source Four Ellipsoidal style

fixture yokes
Includes attached model specific lamp

burner
UL/cUL Listed to UL508
DMX 512 compliant
Remote Device Management (RDM)

USITT / ANSI E1.20 standard
Operating environment maximum

ambient of 50°C with humidity levels

between 10-95%, non-condensing.

Mounting

Installs to the left side of a Source Four yoke with

supplied hardware.
Eight mounting options are available including horizontal,

vertical, top and bottom mounting holes.

Lamp Burner

Lamp burner is specific

to the model of fixture it

will be installed to.

Available models include

ellipsoidal, jr, and PAR

style.

User Interface

Simple three character display

with a three button interface providing

local manual control.
A “Status LED” provides feedback
DMX In and DMX Thru on XLR style connector
RDM configuration
Supports three output curves (modified through

RDM)

Power Input

Supplied by default with a 3’ (.914m) bare-

end power input cord or can be supplied with

a factory installed connector (Edison, Twist-

Lock, or Stage-Pin).
120V or 230/240V input, 50/60Hz, drives a

115V, 375W, 575W or 750W HPL lamp.

Model

Description

Notes

Weight

S4Dim-S4

S4Dim-PAR

S4Dim-JR

(dimmer only)

4.25 lbs

1.93 kg

S4 Dimmer with Ellipsoidal lamp burner kit

S4 Dimmer with PAR lamp burner kit

S4 Dimmer with jr lamp burner kit

Kit includes S4 lamp burner
Kit includes S4 PAR lamp burner and replacement yoke
Kit includes S4 jr lamp burner

Prepare for Installation

Installation of the Source Four Dimmer to a Source Four is simple. Before you begin, please consider the

following very important instructions:

NOTE: Minimum clearance between installed fixtures with the Source Four Dimmer should be no closer

than 18 inches (46 cm) on center.

CAUTION: Do not install the Source Four dimmer positioned

above a fixture that is in a yoke out position.

Dimmer overtemp and failure may occur.

ETC reccomends that the fins of the dimmer be mounted vertically for optimal cooling.

ETC reccommended

mounting with fins

positioned vertically.

Dimmer fins

positioned

horizontally.

NOTE: DMX thru is not self terminating.

Double Clutch Mounting

In order to mount the Souce Four Dimmer to a double clutch fixture such as a Source

Four Zoom, you will need the offset bracket kit; ETC part number 7145K1401.

Step 1: The kit contains two screws and the custom bracket. Use both screws to

attach the bracket to the fixture.
Step 2: Use the screws provided with the dimmer kit to attach the dimmer to the

bracket. Do not attach the dimmer to the yoke as you would with other similar fixtures.

Page 1 of 2

Corporate Headquarters

3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA

Tel +608 831 4116

Fax +608 836 1736

London, UK

Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK

Tel +44 (0)20 8896 1000

Fax +44 (0)20 8896 2000

Rome, IT

Via Pieve Torina, 48, 00156 Rome, Italy

Tel +39 (06) 32 111 683

Fax +44 (0) 20 8752 8486

Holzkirchen, DE

Ohmstrasse 3, 83607 Holzkirchen, Germany

Tel +49 (80 24) 47 00-0

Fax +49 (80 24) 47 00-3 00

Hong Kong

Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong

Tel +852 2799 1220

Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2012 ETC. All Rights Reserved.

Product information and specifications subject to change.

7145M2100

Rev B

Release Date 2012-10

ETC intends this document to be provided in its entirety.