Also see, Plus 7, Color matching – ETC Desire Series XTI v1.6.0 User Manual
Page 28: N o t e

23
Desire XTI Series v1.6.0 User Manual
Plus 7
Plus 7 adds precision color-control channels to the HSI, HSIC, RGB, and Studio profiles.
For example, HSI with Plus 7 enabled becomes a 14-channel profile. Placing channel 7 at
a value over 51% activates the 14-channel profile within the fixture. The desired color and
intensity is achieved by using the HSI or RGB channels as a starting point. Channels 8 to
14 represent the native LED colors of the fixture and allow you to adjust each color up or
down in order to fine-tune the overall color output.
Color Matching
The color output of all Desire fixtures is calibrated at the factory. When operating in the
RGB, HSI, HSIC, or Studio profile, each fixture makes accommodations for the specific
LEDs in its array and produces output that is consistent with other fixtures, whether or not
they utilize LEDs from the same production batch. Operating in the Direct Control profile or
with Plus 7 settings adjustments bypasses this calibration and multiple fixtures may
produce slightly different outputs when controlled as a group.
Studio Daylight, Studio Tungsten Profiles
Direct Control
The first DMX channel always controls Intensity from 0 to 100%.
N o t e :
Depending on the initial color mix, some LED colors may begin at full intensity.
Moving the individual control channels for these colors from 128 to 255 will
produce no effective change from the initial color mix. Conversely, some LED
colors may begin at zero intensity, and moving individual control channels from
128 to 0 will produce no change.
Data Channel
Control
Value
Function
7
Fixture address + 6
Plus 7 control
0 to 129 = Plus 7 disabled
130 to 255 = Plus 7 enabled
Disable or enable Plus 7
control
8
Fixture address + 7
Color 1
a
a) See
128 = No change from initial color
mix
129-255 = Increase from starting
value to full intensity
127-0 = Decrease from starting
value to zero intensity
Alter the individual LED
colors within the array to a
maximum of full intensity
or a minimum of zero
intensity.
9
Fixture address + 8
Color 2
a
10
Fixture address + 9
Color 3
a
11
Fixture address + 10
Color 4
a
12
Fixture address + 11
Color 5
a
13
Fixture address + 12
Color 6
a
14
Fixture address + 13
Color 7
a
Data Channel
Control
Value
Function
1
Fixture address
Intensity
0 to 255
Intensity 0 to 100%
2
Fixture address + 1
Strobe
0 to 255
Variable strobe control