4.5.2.

Digital Output Interface

Feature

Details

Connector Location

Type of output

Optically isolated

Open collector and open emitter

Digital Output Schematic

Maximum supply output
(VCC)

30 V

Max. output current
I

out

(max) (V

out

= Low)

I

out

(max) ≤ 15 mA

VOL at maximum output
voltage (low level)

V

out

(on) ≤ 0.3 V + 0.02 * I

out

(mA)

R

L

The external resistor R

L

must be

selected to limit the output current
to no more than 15 mA.

Executable time

If output is set to one of the built-in

functions — Home flag, Brake or

AOK — execution is immediate upon

detection:

0 < T < 4 x TS
If output is set to General output

and is executed from a program, the

typical time is approximately 0.5

msec.

4.5.3.

Analog Input

Feature

Details

Maximum operating differential voltage

± 10 V

Maximum absolute differential input voltage

± 16 V

Differential input resistance

3.74 kΩ

Analog input command resolution

14-bit