Before You Begin

Receiving

The shipment should be thoroughly inspected as soon as it is

received. The signed bill of lading is acknowledgement, by the
carrier, of receipt in good condition of the shipment covered by
our invoice.

If any of the goods called for on this bill of lading are shorted

or damaged, do not accept them until the carrier makes a nota-
tion of the shorted or damaged goods on the freight bill. Do this
for your own protection.

NOTIFY THE CARRIER AT ONCE if any hidden loss or damage

is discovered after receipt and request him to make an inspec-
tion. If the carrier will not do so, prepare an affidavit to the effect
that you have so notified the carrier (on a certain date) and that
he has failed to comply with your request.

IT IS DIFFICULT TO COLLECT FOR LOSS OR DAMAGE AFTER

YOU HAVE GIVEN THE CARRIER A CLEAR RECEIPT.

File your claim with the carrier promptly. Support your claim

with copies of the bill of lading, freight bill, invoice, and photo-
graphs, if possible.

Although COATS responsibility ceases upon delivery of the

shipment to the carrier, we will gladly assist in tracing lost ship-
ments. Our willingness to assist in every possible manner does
not make COATS responsible for collection of claims, or replace-
ment of lost or damaged materials.

Electrical Requirements

The IBS 2000 requires a 220 VAC, 60Hz, three-phase power

supply with 20 amp fuse or circuit breaker, or a 220 VAC, 60HZ,
single-phase power supply with 20 amp fuse or circuit breaker.

The three-phase balancer is equipped with an approved cord

and a 4-prong grounding plug to fit a Hubbell 2420 or Bryant
71520 grounding receptacle (not included). See figure 1.

The single-phase balancer is equipped with an approved cord

and a 3-prong grounding plug to fit a Hubble 2323 or Bryant
grounding receptacle (not included). See figure 2.

A qualified electrician should install the receptacles in accor-

dance with state and local codes.

Specifications

• Cycle time . . . . . . . . . . . . . . . . . . . . .4 to 5 seconds (avg.)

• Outside Tire Diameter . . . . . . . . . . . . . . . . .44 inches max.

• Wheel Diameter Range . . . . . . . . . . . . . . .8 to 29.9 inches

• Wheel Width Range . . . . . . . . . . . . . . . . . . .2 to 19 inches

• Balancing Increments . . . . . . . . . . . . . .0.25 or 0.01 ounce

• Resolution (Round Off Mode) . . . . . . . . . .0.01 ounce, 1.4°

• Motor - Modified torque with 900 RPM/1.5 HP rating, forced

air cooling, large housing for heat dissipation, and heavy
duty insulation for high temperature applications.

• Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . .625 pounds

Direct Drive

COATS IBS 2000 Interactive Balancing System • 1

Figure 1 - Three-Phase Wiring Diagram

Three-Phase

Ground

Hot

195-230 V
Between
Hot Wires

Hot

Hot

Figure 2 - Single-Phase Wiring Diagram

Single-Phase

A – Red

B – Black

Green/

Ground