beautypg.com

Direct drive, Warning caution – COATS IBS 2000 Wheel Balancer User Manual

Page 20

background image

14 • COATS IBS 2000 Interactive Balancing System

Direct Drive

Maintenance

The balancer requires only minor maintenance to

keep the unit operating properly.

1. Keep the display clean and clear. Use a vaporizing

cleaner only. Do not use cleaners or solvents which
leave oily or filmy residues behind.

2. Keep the adapters, cones, faceplate, threaded

arbor, pressure cup, and hub nut clean. Grease and
dirt buildup will cause premature wear and inaccurate
balancing. Clean these items at least once a day with
a vaporizing solvent.

3. Clean the weight tray, accessory posts, pegs, and

storage shelves with a vaporizing solvent. Weights
stored in a dirty tray will pick up grease and dirt which
may alter their weight or keep them from securely
attaching to the wheel.

Do not hose down or bucket wash the bal-
ancer. Extensive damage to the balancer
will result. Sensitive electronic compo-
nents, wiring harnesses, and other devices
housed in the balancer are not intended to
be exposed to water.

Exposing the balancer to water, either by
hose pipe or bucket, or by exposure to rain
or snow, may cause risk of shock or elec-
trocution to operator or bystanders. Place,
store, and operate the balancer only in a
dry, sheltered location.

4. Keep the area around the balancer clear. Remove

any tools or other items that are leaning against the
balancer. Keep the area under the balancer clear as
well. Remove any items that may cause the balance to
not sit level.

5. Use only COATS accessories. Accessories from

other manufacturers may not fit or function properly,
and may damage the balancer.

Total Accuracy

Verification

The IBS 2000 includes software that will prompt the

user to check the accuracy of his machine periodically.
The procedure is accomplished as follows:

1. Go to the main menu and select Setup. Press

enter.

2. Arrow through the selections to TAV. Press enter.

3. The menu will now display several "preset" selec-

tions to choose from, or the customer may wish to
SPECIFY (choosing your own). The default is 5000
cycles. Press enter.

4. If SPECIFY (choose your own) is selected, the

menu will prompt to enter the number of cycles
desired. Enter the number and press enter.

5. After the balancer reaches the selected number

of cycles the customer will receive THE MESSAGE.
Do you wish to perform T.A.V.? YES or NO.

6. If NO is is selected, the balancer will return to

normal balancing mode.

7. If YES is selected, the balancer will switch to cal-

ibration.

8. Follow the instructions on the display and per-

form normal calibration.

WARNING

CAUTION