7 info menu, 7 info menu -17 – CiDRA SONARtrac HD GVF-100 User Manual
Page 95

Copyright © 2006 CiDRA Corporation
Page 10-17
20675-02 Rev 01
•
Clear History
Will delete transmitter stored Data History and re-start saving of
transmitter data.
•
Param Edit
This is a diagnostic feature rarely used and should only be used under
the direction of CiDRA personnel. Contact CiDRA Technical Support.
•
Monitor
Displays a set of various ‘System’ or ‘Sensor’ parameters, updated at
the display update rate, Used by Factory Technical Support
personnel.
10.1.7 Info
Menu
The ‘Info’ menu allows the user to get detailed information on the flow
monitoring system. The
↑ and ↓ keys scroll through the pages in the
Info menu.
•
Revisions
Provides a multi-page list of installed system revisions, hardware /
software serial / model numbers and part numbers.
•
Diagnostics
Provides a multi-page list of system, temperatures, voltages, and
status messages.
•
Configuration
Provides a multi page list (summary) of system setup parameters.
•
Event Log
–
Displays a list of events, stored in non-volatile memory, with a time-
offset indicating the time since power-up that the event occurred.
Pressing the up and down arrow keys will page up and down through
all events. Pressing the ‘
→’ arrow will display a prompt to erase the
‘Event Log’. Press ‘
→’ arrow again to erase. To cancel the erase
function, press any key other than ‘ENT’.