CiDRA SONARtrac HD GVF-100 User Manual
Page 75
![background image](/manuals/556409/75/background.png)
Copyright © 2006 CiDRA Corporation
Page 9-22
20675-02 Rev 01
Table 14 Transmitter Menu Tree Software Release 03.03.XX (page 7)
Level 1
Level 2
Level 3
Range
Description
IP Address
0.0.0.0 to
255.255.255.255
Current IP address
Ethernet
Subnet Mask
0.0.0.0 to
255.255.255.255
Current Subnet Mask
Baud Rate
2400 to 115200
Serial baud rate
Serial
Options
Config
RS232 or RS485
Serial communications
protocol type
Preambles
5 - 20
# Preamble chars
ahead of MSG
Resp.
Preambles
5 - 20
# Preambles in
response from
transmitter. Change to
match HART
communicator
Univ. Cmd.
Rev.
5 or 6
Major protocol Revision
5, or Revision 6
Polling
Address
0 - 15
Non-zero for multi-drop
connections
=0 for single connection
HART
Find Device
Arm
Enable, Disable
When ‘Enabled”, makes
transmitter respond to
HART “Find Device”
command
Communications
Reset
Comms
Resets communications
ports without re-booting
transmitter