6
Table Limit Switch (TLS) Installation Instructions
WARNING:
Electrocution or serious injury may result when working on an
energized circuit.
Disconnect power at the main breaker or service disconnect switch
before working on the circuit.
Lock-out and tag the breaker to indicate that work is being
performed on the circuit.
Section 5: Wiring Between the TLS and the Dishwasher.
1. Disconnect power to the dishwasher at the main service disconnect switch and tag the circuit to
indicate that work is being performed on the circuit. All wiring and connections must be
performed in accordance with local electrical codes or in the absence of local codes, the National
Electrical Code.
2. Refer to Fig. 7, TLS Conduit Routing, below.
Flexible liquid tight conduit and two wire conductors must be run between the TLS and the
Rinse Tank Terminal Block located in the rinse tank junction box on the front of the rinse tank.
The heavy black lines represent the conduit routing between the TLS and rinse tank junction box.
3. Conduit, connectors, terminals and cable ties are not included in the kit.
4. The length of conduit and wire runs are determined by the installation dimensions.
TLS
TLS
Left to Right Operation
Right to Left Operation
Dishwasher
Wash Tank
Rinse Tank
Rinse Tank Terminal Block
Dish Table
Dish Table
Dishwasher
Wash Tank
Rinse Tank
Rinse Tank Terminal Block
Fig. 7 -
TLS Conduit Routing
(Drawing Not to Scale)