Figure 3.39 System Log Setting WebUI
Enable Log Event to Flash: This would write log events to the local flash.
Log Level: 3 (Currently we only allow this level)
Enable Syslog Server: Enabling this option would allow you to send Syslog events to a remote Syslog server.
Syslog Server IP: Please specify the remote Syslog Serve IP.
Syslog Server Service Port: Please specify the remote Syslog Serve Port.
Figure 3.40 COM Log Setting WebUI
Log Data Contents: If enabled, the COM logging function will log data content. If disabled, COM logging function
will only log data length to reduce system load.
Note that the local flash storage has a very
limited space. If the reserved space is full new logs will replace the old logs. We strongly
recommend sending COM logs to a remote Syslog server.
Data Log Types: Hex or ASCII
COM 1~4 : Choose which port to log.
Enable Syslog Server: Enabling this option would allow you to send COM logs to a remote Syslog server. You can
send COM logs to the same Syslog server used previously.